Brand Name : KACISE
Model Number : KGD-MQ-504
Certification : CE
Place of Origin : CHINA
MOQ : 1PCS
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components : CO/CO₂/CH₄/H₂/O₂/C₂H₂/C₂H₄/CₙHₘ/Calorific Value
Measurement Principle : CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: NDIR; H₂: TCD; O₂: ECD
Measurement Range : CO/CO₂/CH₄/H₂: (0 - 100)%; O₂: (0 - 25)%
Explosion - proof Grade : Ex d ⅡC T4 Gb
The KGD-MQ-504 on-line gas analysis system is specifically designed for challenging working conditions where sample gas contains dust, moisture, and tar. The system comprises three main components: a pretreatment unit, a control unit, and a gas analysis unit.
Utilizing non-dispersive infrared (NDIR) gas analysis technology with independent intellectual property rights, this system can simultaneously and continuously measure the calorific value of coal gas and biogas online. It also measures volume concentrations of gases including CO, CO₂, CH₄, H₂, O₂, and CₙHₘ, while calculating calorific values. This capability enhances coal gas utilization efficiency, promotes energy conservation, reduces consumption, and ensures industrial site safety.
| Items | Details |
|---|---|
| Measured Components | CO/CO₂/CH₄/H₂/O₂/C₂H₂/C₂H₄/CₙHₘ/Calorific Value |
| Measurement Principle | CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: NDIR; H₂: TCD; O₂: ECD |
| Measurement Range | CO/CO₂/CH₄/H₂: (0-100)%; O₂: (0-25)% Accuracy: O₂: (0-25)%; C₂H₂/C₂H₄/CₙHₘ: (0-10)% (Optional) |
| Accuracy | CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: ±1%F.S.; H₂/O₂: ±2%F.S. |
| Explosion-proof Grade | Ex d ⅡC T4 Gb |
| Electrical Parameters | Display: LCD Display Communication: RS-232/RS-485, (4-20)mA, Ethernet |
| Functional Configuration | Equipped with self-diagnosis function for sensor status checking Internal circulation air source available for in-line air self-adjustment |
|
|
Online Gas Analysis System with NDIR Measurement Principle for Multi-component Gas Detection and Ex d ⅡC T4 Gb Explosion-proof Images |