| Sign In | Join Free | My infospaceinc.com |
|
Accuracy : ±1.5mg/m (Range < 10mg/m³), ±15% (Range > 10mg/m³)
Response Time : T10 - 90 < 20s
Measurement Range : 0 < PM Concentration < 25mg/m³
Ignition Time : <750s at a soot concentration of 3mg/m³, <300s at a soot concentration of 8mg/m³
Brand Name : KACISE
Model Number : KGD-326
Certification : CE
Place of Origin : CHINA
MOQ : 1PCS
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Maximum Gas Temperature : Continuous heating to 850°C peak temperature: up to 950°C, lasting 5x60s. During sensor operation < 400°C
The particulate matter sensor KGD - 326 measures cumulative particulate matter (soot) mass in exhaust gas downstream of Diesel Particulate Filters (DPF) to evaluate DPF efficiency. Installed on Selective Catalytic Reduction (SCR) catalyst pipelines, this sensor combines a probe and electronic control module that communicates with the Powertrain Control Module (PCM) via J1939 data link.
| Parameter | Specification |
|---|---|
| Measurement Range | 0 < PM Concentration < 25mg/m³ |
| Accuracy | ±1.5mg/m (Range < 10mg/m³), ±15% (Range > 10mg/m³) |
| Response Time | T10 - 90 < 20s |
| Maximum Gas Temperature | Continuous heating to 850°C peak temperature: up to 950°C, lasting 5x60s. During sensor operation < 400°C |
| Ignition Time | <750s at 3mg/m³ soot concentration, <300s at 8mg/m³ soot concentration |
The probe contains three critical components: a high-efficiency heater, precision temperature sensor, and high-resistance particulate matter measuring electrodes for accurate detection.
|
|
Particulate Matter Sensor KGD - 326 for Measuring Diesel Particles Images |