Max. process pressure : PN 40, Class 300, 20K

Model Number : Proline Promass H 300

MOQ : 1pcs

Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram

Supply Ability : 1000 Piece/Pieces per Week negotiable

Delivery Time : 5-8 work days

Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available

Measuring range : 0 to 70 000 kg/h (0 to 2570 lb/min)

Brand Name : Endress+Hauser

Certification : CE

Contact Now

Proline Promass H 300 Coriolis Flowmeter
Chemically resistant single-tube flowmeter with a compact, easily accessible transmitter. Highly accurate measurement of liquids and gases in applications requiring maximum corrosion resistance.
Field of Application
The highly accurate Promass H is designed for applications requiring maximum corrosion resistance and guarantees optimal safety for chemically aggressive fluids. With its compact transmitter, the Promass H 300 offers high flexibility in operation and system integration.
Key Benefits
  • Maximum safety for chemically aggressive fluids with corrosion-resistant wetted parts
  • Fewer process measuring points through multivariable measurement (flow, density, temperature)
  • Space-saving installation with no inlet/outlet run requirements
  • Full access to process and diagnostic information with numerous, freely combinable I/Os and Ethernet
  • Reduced complexity and variety through freely configurable I/O functionality
  • Integrated verification via Heartbeat Technology
Technical Specifications
Measuring Principle: Coriolis
Nominal Diameter: DN 8 to 50 (3/8" to 2")
Measuring Range: 0 to 70,000 kg/h (0 to 2,570 lb/min)
Max Process Pressure: PN 40, Class 300, 20K
Measurement Accuracy
Measurement Type Accuracy
Mass Flow (Liquid) ±0.10%
Volume Flow (Liquid) ±0.10%
Mass Flow (Gas, Tantalum only) ±0.50%
Density (Liquid) ±0.0005 g/cm³
Temperature Ranges
Material Temperature Range
Tantalum -50 to +150 °C (-58 to +302 °F)
Zirconium -50 to +205 °C (-58 to +401 °F)
Ambient (Standard) -40 to +60 °C (-40 to +140 °F)
Ambient (Option) -50 to +60 °C (-58 to +140 °F)
Wetted Materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702)
Measured Variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Communication & Connectivity
Digital communication: HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Certifications & Approvals
Hazardous area: ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety: CE, C-tick, EAC marking
Functional safety: IEC 61508/IEC 61511 compliant
Pressure: PED, CRN
Material: 3.1 material certificate

Product Tags:

Proline Promass H 300 flowmeter

      

Coriolis flowmeter with warranty

      

Electromagnetic flow meter for industrial use

      
Quality Proline Promass H 300 Coriolis flowmeter for sale

Proline Promass H 300 Coriolis flowmeter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)