System : Menu-driven software, with multi-point calibration function and binding programming, can set the measurement range, relay and current output;
Range : 0~4000 NTU
sensor:Cable Length : Standard 10 meters (extendable)
Host:Protection Level : IP65
Operating Temperature : 0-50℃
Pressure : 0.6MPa
Calibrate : It has been calibrated before delivery and no calibration is needed on site
KLT900 online turbidity meter twater quality stainless steel probe water proof Lightning proof enclosure
Production Introduction
The optical method is often used to measure the turbidity of liquid by comparing with the standard turbidity.The turbidimeter uses the principle of 90° scattered light to accurately measure the turbidimetric value of the tested sample compared with the standard Turbidimetric solution of Formazin.
With its unique software function, the scattered light turbidimeter ensures the accuracy and reliable stability of the instrument.It is widely used in the determination of liquid turbidity in industrial and mining, medical treatment, environmental protection, food, brewing, textile, chemical and other departments.
The ratio of scattered light to transmitted light is taken to measure the turbidity of liquid.The tungsten lamp as light source, light through the lens and color filter, all the way through the measured turbidity liquid transmission to cell 1 received, the other all the way through the liquid 2 receive 90 °scattering to the cell, acoustic signal by the op-amp signal processing after A/D conversion, data processing by single chip microcomputer, through the keyboard control measurement showed that the liquid turbidity value and print output.
Measuring principle
TSS turbidity/suspended matter concentration meter work principle as shown in figure 1-1, sensor transmitter to send the red outside light in transit after being measured the absorption and scattering of content, part of the scattering light to 135°direction of detector, part of the scattering light detector to 90°direction.The light intensity in the direction of 135°and 90°is related to the turbidity of the measured sewage to a certain extent, and the TURBidity of TSS is precisely based on this principle for measurement.
Turbidity meter size structure diagram
host size
sensor size
Turbidity meter technical parameters
Performance | value |
System | Menu-driven software, with multi-point calibration function and binding programming, can set the measurement range, relay and current output; |
Supply | AC220V (min85V- max265V) 50/60Hz |
Maximum power consumed | 15 VA |
Fuse | 2A /220VAC |
Range | 0~4000 NTU |
Measurement Unit | NTU and mg/L are available. |
Resolution Rate | 0.1NTU |
Accuracy | 2% of the measured value, within 10NTU the error is not greater than 1NTU. |
Display | The display screen is 192 × 64 pixels, which can display turbidity measurement value, current time, historical trend line, etc. |
Principle | infrared light scattering 90° and 135° |
Output | 1 channel 4~20mA current signal isolation output, maximum load 750 ohms; 1-channel RS232 and 1-channel RS485 digital output (optional); 3 alarm signal relays, capacity 220 VAC/ 2 A, output can be set by the user; |
Host:Material | ABS+PC |
Host:Protection Level | IP65 |
Sensor Material | 316L stainless steel |
Cable Length | Dedicated shield cable, standard 10 meters (extendable) |
Operating Temperature | 0-50℃ |
Pressure | 0.6MPa |
Calibrate | It has been calibrated before delivery and no calibration is needed on site |
Ordering Information Selection Table
Ordering Information Selection Table | ||
KXTX00 | PH/ORP analyzer | |
Power supply | DC24V | |
AC220V | ||
Cable length | 5m | |
10m | ||
15m | ||
20m | ||
Temperature compensation | Sensor without temperature compensation | |
Sensor with temperature compensation | ||
Signal output | Only 4-20mA | |
Only 485 | ||
Also with 4-20mA , 485 signal output | ||
Special custom signal | ||
KLT500-DC24V--5m-Sensor without temperature compensation-Only 485 | Low Turbidity host, with DC 24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication. |
Cautions
The following points should be noted during the use of the scattered light turbidimeter:
(1) The power supply of the instrument must have a good ground wire, so as to avoid the adverse consequences such as unstable measurement data.
(2) There should be no water marks, water vapor, bubbles and other impurities on the surface of the test tube. The surface should be kept dry and clean, otherwise the measurement accuracy and stability will be affected.
(3) The turbidity liquid to be measured is injected into the test tube. Because the movement of small particles in the liquid affects the measurement of the scattered light, the sample is inserted into the sample room 30 seconds after it is injected into the test tube, and the data is read out and printed after the display is stable.
Contact us
Website: www.kacise.com
Phone: +86-17719566736
Email: sales@kacise.com
Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
Abbreviations table
NTU
The unit of turbidity is "degree", which is equivalent to the degree of turbidity produced by 1L water containing 1mg SiO2 (or white clay, diatomite), which is 1 degree, or Jackson.Turbidity unit is JTU, 1JTU=1mg/L white clay suspension.
The turbidity shown by modern instruments is the unit of scattering turbidity NTU, also known as TU.1NTU= 1JTU.
Recently, it is considered internationally that the standard of turbidity prepared with ullotropin-hydrazine sulfate has good reproducibility and is chosen as the uniform standard of FTU.1FTU=1JTU.